B8 VW Passat 2014 how to adjust the operating time of the heater. Coding and diagnostics using the KKL Adapter and VAG COM, VCDS, VAS, VCP, ODIS, etc. Collection of codings VAG Group

AvtoAd
27/05/2022
Adjust the operating time of the heater as follows:
1. Choose the Address of the central electricity control unit 09 .
2. Select function 16 Secure access.
3. Enter the unlock code 31347 .
4. Select function 10 Adaptations.
5. Select the value "Heater heater" .
6. Adjust the value according to the default target value: 600 sec.
Done!